Bitte benutzen Sie diese Kennung, um auf die Ressource zu verweisen: http://dx.doi.org/10.25673/38191
Titel: Intraoperative quantification of floating mass transducer coupling quality in active middle ear implants : a multicenter study
Autor(en): Fröhlich, LauraIn der Gemeinsamen Normdatei der DNB nachschlagen
Rahne, Torsten
Plontke, Stefan K.-R.In der Gemeinsamen Normdatei der DNB nachschlagen
Oberhoffner, Tobias
Dahl, Rüdiger
Mlynski, Robert
Dziemba, Oliver
Aristeidou, Aristotelis
Gadyuchko, Maria
Koscielny, Sven
Hoth, Sebastian
Kropp, Miriam H.
Mir-Salim, Parwis
Müller, Alexander
Erscheinungsdatum: 2020
Art: Artikel
Sprache: Englisch
Zusammenfassung: Purpose: Evaluating the effectiveness of intraoperative auditory brainstem responses (ABRs) to stimulation by the Vibrant Soundbridge (VSB) active middle ear implant for quantifying the implant’s floating mass transducer (FMT) coupling quality. Methods: In a diagnostic multicentric study, patients (> 18 years) who received a VSB with different coupling modalities were included. Pre- and postoperative bone conduction thresholds, intraoperative VSB-evoked ABR thresholds (VSB-ABR) using a modified audio processor programmed to preoperative bone conduction thresholds, postoperative vibrogram thresholds, and postoperative VSB-ABR thresholds were measured. Coupling quality was calculated from the difference between the pure tone average at 1000, 2000, and 4000 Hz (3PTA) vibrogram and postoperative 3PTA bone conduction thresholds. Results: Twenty-three patients (13 males, 10 females, mean age 56.6 (± 12.5) years) were included in the study. Intraoperative VSB-ABR response thresholds could be obtained in all except one patient where the threshold was > 30 dB nHL. Postoperatively, an insufficient coupling of 36.7 dB was confirmed in this patient. In a Bland–Altman analysis of the intraoperative VSB-ABRs and coupling quality, the limits of agreement exceeded ± 10 dB, i.e., the maximum allowed difference considered as not clinically important but the variation was within the general precision of auditory brainstem responses to predict behavioral thresholds. Five outliers were identified. In two patients, the postoperative VSB-ABR thresholds were in agreement with the coupling quality, indicating a change of coupling before the postoperative testing. Conclusion: The response thresholds recorded in this set-up have the potential to predict the VSB coupling quality and optimize postoperative audiological results.
URI: https://opendata.uni-halle.de//handle/1981185920/38434
http://dx.doi.org/10.25673/38191
Open-Access: Open-Access-Publikation
Nutzungslizenz: (CC BY 4.0) Creative Commons Namensnennung 4.0 International(CC BY 4.0) Creative Commons Namensnennung 4.0 International
Sponsor/Geldgeber: Publikationsfond MLU
Journal Titel: European archives of oto-rhino-laryngology and head & neck
Verlag: Springer
Verlagsort: Berlin
Band: 278
Originalveröffentlichung: 10.1007/s00405-020-06313-z
Seitenanfang: 2277
Seitenende: 2288
Enthalten in den Sammlungen:Open Access Publikationen der MLU

Dateien zu dieser Ressource:
Datei Beschreibung GrößeFormat 
Fröhlich2021_Article_IntraoperativeQuantificationOf.pdf595.53 kBAdobe PDFMiniaturbild
Öffnen/Anzeigen