Please use this identifier to cite or link to this item:
http://dx.doi.org/10.25673/1587
Title: | Vergleichswerterstellung für die Acoustic-Radiation-Force-Impulse-Elastographie der Leber im Kinder- und Jugendalter |
Author(s): | Weinitschke, Kristin |
Referee(s): | Spielmann, Rolf Peter, Prof. Dr. Alzen, Gerhard, Prof. Dr. Mentzel, Hans-Joachim, Prof. Dr. |
Granting Institution: | Martin-Luther-Universität Halle-Wittenberg |
Issue Date: | 2015 |
Extent: | Online-Ressource (76 Bl. = 6,71 mb) |
Type: | Hochschulschrift |
Type: | PhDThesis |
Exam Date: | 2015-09-22 |
Language: | German |
Publisher: | Universitäts- und Landesbibliothek Sachsen-Anhalt |
URN: | urn:nbn:de:gbv:3:4-15706 |
Subjects: | Online-Publikation Hochschulschrift |
Abstract: | Die Acoustic-Radiation-Force-Impulse (ARFI)-Elastographie ist ein wertvolles, non-invasives Werkzeug zur Beurteilung der Lebersteifigkeit. Ziel der Studie war die Bestimmung von Vergleichswerten für die ARFI-Elastographie der Leber bei gesunden Kindern. Es wurden 235 lebergesunde Kinder zwischen 5 und 18 Jahren an einem Siemens S2000 untersucht. Die ARFI- Geschwindigkeiten wurden mit dem 4C1- Schallkopf an drei Messpunkten in beiden Schallkopforientierungen jeweils doppelt bestimmt. Messungen im rechten Leberlappen ergaben niedrigere ARFI- Werte als Messungen im linken Leberlappen (1.25 m/s vs. 1.31 m/s). Die geringste Streuung zeigten Messungen in der vorderen Axillarlinie in transversaler Einstellung. Mit zunehmendem Alter nehmen die ARFI- Werte leicht ab. Bei erhöhtem BMI liegt eine gesteigerte Messwertstreuung vor. Acoustic-Radiation-Force-Impulse (ARFI)-Elastography is a valuable, easy to use tool for the sonographic assessment of liver stiffness. The aim of our study was to determine normal ARFI- values in healthy children and adolescents. 235 healthy children between the ages of 5 and 18 years were examined using a Siemens Acuson S2000. The ARFI- velocities were obtained with the 4C1- transducer twice at a time in both transducer orientations at three measuring sites.Measurements in the right liver lobe resulted in significantly lower ARFI- values than measurements in the left liver lobe (1.25 m/s vs. 1.31 m/s). Measurements in the anterior axillary line in transversal transducer orientation showed the lowest scattering. There was a low negative correlation between measured ARFI- velocities and patient’s age. An elevated BMI resulted in a higher variance of the obtained ARFI- velocities. |
URI: | https://opendata.uni-halle.de//handle/1981185920/8358 http://dx.doi.org/10.25673/1587 |
Open Access: | Open access publication |
License: | In Copyright |
Appears in Collections: | Medizin und Gesundheit |
Files in This Item:
File | Description | Size | Format | |
---|---|---|---|---|
Diss zur Veröffentlichung.pdf | 6.87 MB | Adobe PDF | View/Open |