Bitte benutzen Sie diese Kennung, um auf die Ressource zu verweisen: http://dx.doi.org/10.25673/36537
Langanzeige der Metadaten
DC ElementWertSprache
dc.contributor.authorVoß, Samuel-
dc.contributor.authorBeuing, Oliver-
dc.contributor.authorJaniga, Gábor-
dc.contributor.authorBerg, Philipp-
dc.date.accessioned2021-05-06T08:43:19Z-
dc.date.available2021-05-06T08:43:19Z-
dc.date.issued2019-
dc.date.submitted2019-
dc.identifier.urihttps://opendata.uni-halle.de//handle/1981185920/36770-
dc.identifier.urihttp://dx.doi.org/10.25673/36537-
dc.description.abstractBackground Image-based blood flow simulations have been increasingly applied to investigate intracranial aneurysm (IA) hemodynamics. However, the acceptance among physicians remains limited due to the high variability in the underlying assumptions and quality of results. Methods To evaluate the vessel segmentation as one of the most important sources of error, the international Multiple Aneurysms AnaTomy CHallenge 2018 (MATCH) was announced. 26 research groups from 13 different countries segmented three datasets, which contained five IAs in total. Based on these segmentations, 73 time-dependent blood flow simulations under consistent conditions were carried out. Afterwards, relevant flow and shear parameters (e.g., neck inflow rate, parent vessel flow rate, spatial mean velocity, and wall shear stress) were analyzed both qualitatively and quantitatively. Results Regarding the entire vasculature, the variability of the segmented vessel radius is 0.13 mm, consistent and independent of the local vessel radius. However, the centerline velocity shows increased variability in more distal vessels. Focusing on the aneurysms, clear differences in morphological and hemodynamic parameters were observed. The quantification of the segmentation-induced variability showed approximately a 14% difference among the groups for the parent vessel flow rate. Regarding the mean aneurysmal velocity and the neck inflow rate, a variation of 30% and 46% was observed, respectively. Finally, time-averaged wall shear stresses varied between 28% and 51%, depending on the aneurysm in question. Conclusions MATCH reveals the effect of state-of-the-art segmentation algorithms on subsequent hemodynamic simulations for IA research. The observed variations may lead to an inappropriate interpretation of the simulation results and thus, can lead to inappropriate conclusions by physicians. Therefore, accurate segmentation of the region of interest is necessary to obtain reliable and clinically helpful flow information.eng
dc.description.sponsorshipDFG-Publikationsfonds 2019-
dc.language.isoeng-
dc.relation.ispartofhttps://journals.plos.org/plosone/-
dc.rights.urihttps://creativecommons.org/licenses/by/4.0/-
dc.subjectImage-based blood simulationeng
dc.subjectIntracranial aneurysm (IA)eng
dc.subjectHemodynamiceng
dc.subject.ddc660-
dc.titleMultiple Aneurysms AnaTomy CHallenge 2018 (MATCH)—Phase Ib : effect of morphology on hemodynamics-
dc.typeArticle-
dc.identifier.urnurn:nbn:de:gbv:ma9:1-1981185920-367706-
local.versionTypepublishedVersion-
local.bibliographicCitation.journaltitlePLOS ONE-
local.bibliographicCitation.volume14-
local.bibliographicCitation.issue5-
local.bibliographicCitation.pagestart1-
local.bibliographicCitation.pageend16-
local.bibliographicCitation.publishernamePLOS-
local.bibliographicCitation.publisherplaceSan Francisco, California, US-
local.bibliographicCitation.doi10.1371/journal.pone.0216813-
local.openaccesstrue-
dc.identifier.ppn1678823368-
local.bibliographicCitation.year2019-
cbs.sru.importDate2021-05-06T08:35:26Z-
local.bibliographicCitationEnthalten in PLOS ONE - San Francisco, California, US : PLOS, 2006-
local.accessrights.dnbfree-
Enthalten in den Sammlungen:Fakultät für Verfahrens- und Systemtechnik (OA)

Dateien zu dieser Ressource:
Datei Beschreibung GrößeFormat 
Voss et al._Multiple_2019.pdfZweitveröffentlichung3.96 MBAdobe PDFMiniaturbild
Öffnen/Anzeigen