Please use this identifier to cite or link to this item:
http://dx.doi.org/10.25673/3490
Full metadata record
DC Field | Value | Language |
---|---|---|
dc.contributor.referee | Duncker, Gernot I. W. | - |
dc.contributor.author | Vogt, Ralf | - |
dc.date.accessioned | 2018-09-24T13:54:08Z | - |
dc.date.available | 2018-09-24T13:54:08Z | - |
dc.date.issued | 2004 | - |
dc.identifier.uri | https://opendata.uni-halle.de//handle/1981185920/10275 | - |
dc.identifier.uri | http://dx.doi.org/10.25673/3490 | - |
dc.description.abstract | Hintergrund: Tagesprofile zu Praxiszeiten erfassen oft nicht genügend Messwerte, v. a. nachts und morgens. Die Selbsttonometrie könnte ohne stationären Aufenthalt echte 24-Stunden-IOD-Tagesprofile ermöglichen. Methoden: 96 Personen wurden in die Selbsttonometrie mit dem automatischen Selbsttonometer "Ocuton S ®" eingewiesen. Bei den Probanden, die die Selbsttonometrie erlernen konnten, wurden synchron IOD-Tagesprofile eines Auges nach Goldmann und mit Selbsttonometrie unter stationären Bedingungen sowie ein Tagesprofil durch Selbsttonometrie des gleichen Auges unter ambulanten Bedingungen erhoben. Ein Tagesprofil umfasste dabei jeweils 6 Messungen im Zeitabstand von je 4 Stunden. Die ermittelten IOD-Werte wurden statistisch auf Vergleichbarkeit untersucht. Ergebnisse: Von 96 Probanden erlernten 50 die Selbsttonometrie. Die mit den verschiedenen Methoden im Rahmen der Tagesprofile gemessenen IOD-Werte unterschieden sich im Mittel um weniger als 2mmHg und waren damit vergleichbar. Die Tagesdruckkurven waren auch im Hinblick auf den zeitlichen Verlauf zwischen den Methoden nicht signifikant verschieden. Schlussfolgerung: Die Selbsttonometrie mit dem automatischen Selbsttonometer scheint geeignet zu sein zur Gewinnung von Tagesprofilen des intraokularen Druckes unter ambulanten Bedingungen. | - |
dc.description.abstract | Background: Diurnal profiles of intraocular pressure at opening times at the doctor's do not deliver enough information, especially nightly and early morning measures miss. Self-tonometry using automatic self-tonometer "Ocuton S ®" might be suitable to result in valid 24 hour IOP-profiles without staying at a hospital. Methods: 96 people were teached using the automatic self-tonometer once. Those who learned self-tonometry after this training underwent diurnal IOP-profile for 24 hours at the hospital using Goldmann tonometry and self-tonometry every 4 hours at the same times of day. One to three days later, they maintained a third IOP-profile at home using self-tonometry at the same intervals as at the hospital. IOP-profiles were then tested for equality. Results: 50 people out of 96 were able to perform self-tonometry after one training. The IOP-measures of all three IOP-profiles did not differ by more than 2mmHg and thus may be considered comparable. There was no significant difference between daily curves, either. Conclusion: Self-tonometry using automatic self-tonometer "Ocuton S ®" appears to suitable to maintain diurnal profiles of intraocular pressure at home. | eng |
dc.description.statementofresponsibility | von Ralf Vogt | - |
dc.format.extent | Online-Ressource, Text + Image | - |
dc.language.iso | ger | - |
dc.publisher | Universitäts- und Landesbibliothek Sachsen-Anhalt | - |
dc.rights.uri | http://rightsstatements.org/vocab/InC/1.0/ | - |
dc.subject | Tonometrie | - |
dc.subject | Hochschulschrift | - |
dc.subject | Online-Publikation | - |
dc.subject | Zsfassung in engl. Sprache | - |
dc.title | Anwendbarkeit der Selbsttonometrie unter ambulanten Bedingungen zur Gewinnung von Tagesprofilen des intraokularen Druckes | - |
dcterms.type | Hochschulschrift | - |
dc.type | PhDThesis | - |
dc.identifier.urn | urn:nbn:de:gbv:3-000007222 | - |
local.publisher.universityOrInstitution | Martin-Luther-Universität Halle-Wittenberg | - |
local.subject.keywords | Glaukom, intraokularer Druck, Tonometrie, Goldmann-Tonometrtie, Selbsttonometrie, IOD-Tagesprofil, Tagesdruckkurve | - |
local.subject.keywords | Glaucoma, intraocular pressure, tonometry, Goldmann-tonometry, self-tonometry, IOP-profile, diurnal pressure curve | eng |
local.openaccess | true | - |
dc.identifier.ppn | 470212551 | - |
local.accessrights.dnb | free | - |
Appears in Collections: | Hochschulschriften bis zum 31.03.2009 |