Please use this identifier to cite or link to this item:
http://dx.doi.org/10.25673/116896
Full metadata record
DC Field | Value | Language |
---|---|---|
dc.contributor.author | Jonuscheit, Marc | - |
dc.contributor.author | Wierichs, Stefan | - |
dc.contributor.author | Rothe, Maik | - |
dc.contributor.author | Korzekwa, Benedict | - |
dc.contributor.author | Mevenkamp, Julian | - |
dc.contributor.author | Bobrov, Pavel | - |
dc.contributor.author | Kupriyanova, Yuliya | - |
dc.contributor.author | Roden, Michael | - |
dc.contributor.author | Schrauwen-Hinderling, Vera B. | - |
dc.date.accessioned | 2024-10-16T08:51:45Z | - |
dc.date.available | 2024-10-16T08:51:45Z | - |
dc.date.issued | 2024 | - |
dc.identifier.uri | https://opendata.uni-halle.de//handle/1981185920/118856 | - |
dc.identifier.uri | http://dx.doi.org/10.25673/116896 | - |
dc.description.abstract | Concentrations of the key metabolites of hepatic energy metabolism, adenosine triphosphate (ATP) and inorganic phosphate (Pi), can be altered in metabolic disorders such as diabetes mellitus. 31Phosphorus (31P)-magnetic resonance spectroscopy (MRS) is used to noninvasively measure hepatic metabolites, but measuring their absolute molar concentrations remains challenging. This study employed a 31P-MRS method based on the phantom replacement technique for quantifying hepatic 31P-metabolites on a 3-T clinical scanner. Two surface coils with different size and geometry were used to check for consistency in terms of repeatability and reproducibility and absolute concentrations of metabolites. Day-to-day (n = 8) and intra-day (n = 6) reproducibility was tested in healthy volunteers. In the day-to-day study, mean absolute concentrations of γ-ATP and Pi were 2.32 ± 0.24 and 1.73 ± 0.26 mM (coefficient of variation [CV]: 7.3% and 8.8%) for the single loop, and 2.32 ± 0.42 and 1.73 ± 0.27 mM (CVs 6.7% and 10.6%) for the quadrature coil, respectively. The intra-day study reproducibility using the quadrature coil yielded CVs of 4.7% and 6.8% for γ-ATP and Pi without repositioning, and 6.3% and 7.1% with full repositioning of the volunteer. The results of the day-to-day data did not differ between coils and visits. Both coils robustly yielded similar results for absolute concentrations of hepatic 31P-metabolites. The current method, applied with two different surface coils, can be readily utilized in long-term and interventional studies. In comparison with the single loop coil, the quadrature coil also allows measurements at a greater distance between the coil and liver, which is relevant for studying people with obesity. | eng |
dc.language.iso | eng | - |
dc.rights.uri | https://creativecommons.org/licenses/by-nc-nd/4.0/ | - |
dc.subject.ddc | 610 | - |
dc.title | Reproducibility of absolute quantification of adenosine triphosphate and inorganic phosphate in the liver with localized 31P-magnetic resonance spectroscopy at 3-T using different coils | eng |
dc.type | Article | - |
local.versionType | publishedVersion | - |
local.bibliographicCitation.journaltitle | NMR in biomedicine | - |
local.bibliographicCitation.volume | 37 | - |
local.bibliographicCitation.issue | 8 | - |
local.bibliographicCitation.pagestart | 1 | - |
local.bibliographicCitation.pageend | 15 | - |
local.bibliographicCitation.publishername | Wiley | - |
local.bibliographicCitation.publisherplace | New York, NY | - |
local.bibliographicCitation.doi | 10.1002/nbm.5120 | - |
local.openaccess | true | - |
dc.identifier.ppn | 1884939643 | - |
cbs.publication.displayform | 2024 | - |
local.bibliographicCitation.year | 2024 | - |
cbs.sru.importDate | 2024-10-16T08:50:40Z | - |
local.bibliographicCitation | Enthalten in NMR in biomedicine - New York, NY : Wiley, 1988 | - |
local.accessrights.dnb | free | - |
Appears in Collections: | Open Access Publikationen der MLU |
Files in This Item:
File | Description | Size | Format | |
---|---|---|---|---|
NMR in Biomedicine - 2024 - Jonuscheit - Reproducibility of absolute quantification of adenosine triphosphate and inorganic.pdf | 1.31 MB | Adobe PDF | View/Open |