Please use this identifier to cite or link to this item: http://dx.doi.org/10.25673/121783
Full metadata record
DC FieldValueLanguage
dc.contributor.authorKopsch, Anna C.-
dc.contributor.authorPlontke, Stefan K.-R.-
dc.contributor.authorRahne, Torsten-
dc.date.accessioned2026-01-09T07:20:45Z-
dc.date.available2026-01-09T07:20:45Z-
dc.date.issued2025-
dc.identifier.urihttps://opendata.uni-halle.de//handle/1981185920/123734-
dc.identifier.urihttp://dx.doi.org/10.25673/121783-
dc.description.abstractThe electrical signal processing of cochlear implants (CIs) is thought to partially explain the unnatural and unfamiliar sound impressions in recipients. To date, there are no accurate German-language sound samples available that represent how CI users perceive their CIs. The primary aim of this study was to create German-language sound samples for the sound of Cochlear Nucleus implants (Cochlear Ltd., Sydney, Australia). Furthermore, we investigated whether the simulation parameters best matched for one sentence were also accurate approximations of the CI sound when applied to two further sentences spoken by the same male speaker. Fifteen patients with single-sided deafness who had at least two years of experience with their CI were included in this study. The participants rated ten simulations based on the similarity to the sound perceived with their devices. The simulation with the best similarity score served as the starting point for optimization using a software sound-tool. On average, a score of 9.7 ± 0.5 on a scale of 1 (no similarity) to 10 (signals are identical) was achieved for the optimized simulations. Most often, a low-pass filter or a comb filter was required to optimize the simulation. The sound samples optimized for each study participant are provided in the Supplemental Material. When the parameters of the optimized simulation were applied to two further sentences (variable in content and phonemes), the similarity scores were significantly worse (mean sentence 2: 8.4 ± 1.5, Z = 3.015, p = 0.003, mean sentence 3: 8.9 ± 1.3, sign test: Z = 2.268, p = 0.048). However, when the similarity scores were considered individually for each participant, there were 4 (sentence 2) or 7 (sentence 3) participants, respectively, for whom the speech material had no influence on the similarity score.eng
dc.language.isoeng-
dc.rights.urihttps://creativecommons.org/licenses/by/4.0/-
dc.subject.ddc610-
dc.titleAcoustic simulation of cochlear implant sound to approximate the perceptual experience of electric hearingeng
dc.typeArticle-
local.versionTypepublishedVersion-
local.bibliographicCitation.journaltitleScientific reports-
local.bibliographicCitation.volume15-
local.bibliographicCitation.pagestart1-
local.bibliographicCitation.pageend13-
local.bibliographicCitation.publishernameSpringer Nature-
local.bibliographicCitation.publisherplace[London]-
local.bibliographicCitation.doi10.1038/s41598-025-25711-z-
local.openaccesstrue-
dc.identifier.ppn1948142953-
cbs.publication.displayform2025-
local.bibliographicCitation.year2025-
cbs.sru.importDate2026-01-09T07:20:24Z-
local.bibliographicCitationEnthalten in Scientific reports - [London] : Springer Nature, 2011-
local.accessrights.dnbfree-
Appears in Collections:Open Access Publikationen der MLU

Files in This Item:
File Description SizeFormat 
s41598-025-25711-z.pdf1.39 MBAdobe PDFThumbnail
View/Open