Please use this identifier to cite or link to this item: http://dx.doi.org/10.25673/695
Full metadata record
DC FieldValueLanguage
dc.contributor.refereeBöning, K., Prof. Dr.-
dc.contributor.refereeFuhrmann, R., Prof. Dr.-
dc.contributor.refereeSetz, J. M., Prof. Dr.-
dc.contributor.authorHertwig, Juliane-
dc.date.accessioned2018-09-24T10:41:00Z-
dc.date.available2018-09-24T10:41:00Z-
dc.date.issued2012-
dc.identifier.urihttps://opendata.uni-halle.de//handle/1981185920/7595-
dc.identifier.urihttp://dx.doi.org/10.25673/695-
dc.description.abstractZiel dieser Arbeit war es den Zusammenhang zwischen der Abzugskraft dentaler Abformmaterialien und der Shore-A-Härte an einem eigens für diese Studie gefertigtem Modell zu untersuchen. Es wurden 14 Abformmaterialien (A-Silikone, Polyether, Vinylsiloxanether) vom Epoxidkunststoffmodell und nach dem Ausgießen mit Gips abgezogen. Weiterhin wurde die lineare Dimensionsänderung ermittelt. Die Abzugskräfte vom Urmodell lagen im Bereich zwischen 290,80 N und 497,81 N, vom Gipsmodell zwischen 111,40 N und 200,22 N; die Werte unterscheiden sich signifikant (p<0,001). Die Shore-A-Härte befand sich im Bereich zwischen 44,8 und 69,6 zur Zeit des Abzugs vom Urmodell bzw. zwischen 50,9 und 70,3 nach 24 Stunden beim Abzug vom Gipsmodell. Es lag keine Korrelation zwischen der Abzugskraft vom Urmodell und der Shore-A-Härte vor, jedoch eine geringe Korrelation zwischen der Abzugskraft vom Gipsmodell und der Shore-A-Härte ist vorhanden. Die lineare Dimensionsänderung lag zwischen 0,01 % und 0,17 % im Vergleich zum Urmodell, somit sind alle Materialien für die Präzisionsabformung geeignet. Die Herstellerangaben zur Shore-A-Härte sind wenig geeignet um auf klinisch relevante Abzugskräfte zu schließen.-
dc.description.abstractThe aim of this study was to investigate the correlation between the removal forces and the Shore-A-hardness of dental impression materials on a specially made model. 14 impression materials (a-silicons, polyethers, vinysiloxanethers) were removed from the polyurethane model of the teeth and after filling the cast. Furthermore, the linear dimensional alteration was determined. The removal forces for the polyurethane model were in the range between 290.80 and 497.81 N, for the cast model between 111.40 and 200 200.22 N; the values differ significantly (p<0.001). The Shore- A-hardness was in the range 44.8 to 69.6 at the time of removal from the model and varied between 50.9 to 70.3 after 24 hours of the removal from the cast model. No correlation was observed between the removal force of the polyurethane model and the Shore-A-hardness, however, a marginal correlation exists between the removal force of the cast model and the Shore-A-hardness. The linear dimensional alteration was in the range between 0.01% and 0.17% compared with the polyurethane model, all materials are suitable for precision impressions. The interrelationship between the manufacturer's specifications for the Shore-A-hardness and clinically relevant removal forces is of limited suitability.eng
dc.description.statementofresponsibilityvon Juliane Hertwig-
dc.format.extentOnline-Ressource (IV, 49 Bl. = 4,70 mb)-
dc.language.isoger-
dc.publisherUniversitäts- und Landesbibliothek Sachsen-Anhalt-
dc.rights.urihttp://rightsstatements.org/vocab/InC/1.0/-
dc.subjectOnline-Publikation-
dc.subjectHochschulschrift-
dc.subject.ddc617-
dc.titleExperimentelle Untersuchungen zu Abzugskräften bei elastomeren Abformmaterialien-
dcterms.dateAccepted2012-05-08-
dcterms.typeHochschulschrift-
dc.typePhDThesis-
dc.identifier.urnurn:nbn:de:gbv:3:4-7763-
local.publisher.universityOrInstitutionMartin-Luther-Universität Halle-Wittenberg-
local.subject.keywordsAbzugskräfte; Shore-A-Härte; Abformmaterial; lineare Dimensionsänderung; Epoxidkunststoffmodell; Gipsmodell-
local.subject.keywordsremoval forces; Shore-A-Hardness; impression material; linear dimensional alteration; polyurethane model; cast modeleng
local.openaccesstrue-
dc.identifier.ppn716576236-
local.accessrights.dnbfree-
Appears in Collections:Chirurgie und verwandte medizinische Fachrichtungen

Files in This Item:
File Description SizeFormat 
Doktorarbeit - Bibliothek fertig.pdf4.82 MBAdobe PDFThumbnail
View/Open