Please use this identifier to cite or link to this item: http://dx.doi.org/10.25673/802
Full metadata record
DC FieldValueLanguage
dc.contributor.refereeBoeckler, PD Dr.-
dc.contributor.refereeSchaller, Prof. Dr.-
dc.contributor.refereeGeis-Gerstorfer, Prof. Dr.-
dc.contributor.authorBlümel, Nadine-
dc.date.accessioned2018-09-24T10:43:31Z-
dc.date.available2018-09-24T10:43:31Z-
dc.date.issued2012-
dc.identifier.urihttps://opendata.uni-halle.de//handle/1981185920/7702-
dc.identifier.urihttp://dx.doi.org/10.25673/802-
dc.description.abstractAnhand werkstoffkundlicher Parameter sollte geklärt werden, ob die Desinfektion materialtechnische Eigenschaften von PMMA Kunststoffen beeinflusst. Es mangelt an einem ausreichenden Produktangebot. Material und Methoden: Prüfkörper der Kunststoffe PalaXpress [PX], Paladon65 [PD], Futura Gen [FG] und FuturAcryl [FA] wurden hergestellt, die mit Impresept [IM], Stammopur DR (SP) und D050 Instru-Gen [IG] desinfiziert wurden. Ermittelt wurden Biegeeigenschaften, Makro-, Mikrohärte, Rauigkeits- und Farbänderungen nach Desinfektionsmitteleinwirkung. Ergebnisse: SP erhöhte die Rauigkeit von PX. IG bewirkte eine subjektiv wahrnehmbare Farbänderung bei FA (∆E>2). Die Parameter Elastizität, Festigkeit und Makrohärte blieben unbeeinflusst. Nach Desinfektion von PX und GF ergaben sich teilweise erhöhte Mikrohärtewerte. Zusammenfassung: In Bezug auf die aktuell erarbeiteten Ergebnisse kann IM zur Prothesendesinfektion im Sinne einer Erweiterung des Anwendungsspektrums und der Vereinheitlichung von Arbeitsabläufen empfohlen werden.-
dc.description.abstractThis study investigated the influence of chemical disinfectant solutions on several mechanical properties. There are no special products offered, which are appropriate for cleaning and disinfecting dentures. Method: Specimens of 4 denture base resins (PalaXpress [PX], Paladon65 [PD], Futura Gen [FG] and FuturAcryl [FA]) were prepared and disinfected by Impresept [IM], Stammopur DR (SP) and D050 Instru-Gen [IG]. Flexural properties, microhardness, macrohardness, changes in surface roughness and colour were determined after disinfection. Results: SP caused an increase of surface roughness of PX. FA disinfected by IG showed distinctly colour changes (∆E>2). Flexural properties and macrohardness stayed unaffected. For PX and FG an increase in microhardness was partially observed after disinfection. Conclusion: The application of IM on dental prostheses can be recommended under practical conditions in order to simplify disinfection procedures in every day practise.eng
dc.description.statementofresponsibilityvon Nadine Blümel-
dc.format.extentOnline-Ressource (86 Bl. = 0,93 mb)-
dc.language.isoger-
dc.publisherUniversitäts- und Landesbibliothek Sachsen-Anhalt-
dc.rights.urihttp://rightsstatements.org/vocab/InC/1.0/-
dc.subjectOnline-Publikation-
dc.subjectHochschulschrift-
dc.subject.ddc617-
dc.titleDer Einfluss von Desinfektionsmitteln auf die klinischen Eigenschaften von Prothesenkunststoffen-
dcterms.dateAccepted2012-11-07-
dcterms.typeHochschulschrift-
dc.typePhDThesis-
dc.identifier.urnurn:nbn:de:gbv:3:4-8943-
local.publisher.universityOrInstitutionMartin-Luther-Universität Halle-Wittenberg-
local.subject.keywordschemische Desinfektion; Prothesenbasiskunststoffe; Biegefestigkeit; Mikrohärte; Makrohärte; Oberflächenrauigkeit; Farbänderung-
local.subject.keywordsdisinfection; denture base resin; flexural strength; microhardness; macrohardness; surface roughness; colour stabilityeng
local.openaccesstrue-
dc.identifier.ppn733448763-
local.accessrights.dnbfree-
Appears in Collections:Chirurgie und verwandte medizinische Fachrichtungen

Files in This Item:
File Description SizeFormat 
2012-11-27 Promotion.pdf953.98 kBAdobe PDFThumbnail
View/Open