dc.contributor.referee | Lohmann, Christoph H., Prof. Dr. | - |
dc.contributor.referee | Rickert, Markus, Prof. Dr. | - |
dc.contributor.referee | Zeh, Alexander, PD Dr. | - |
dc.contributor.author | Pankow, Franziska | - |
dc.date.accessioned | 2018-09-24T11:09:35Z | - |
dc.date.available | 2018-09-24T11:09:35Z | - |
dc.date.issued | 2014 | - |
dc.identifier.uri | https://opendata.uni-halle.de//handle/1981185920/8118 | - |
dc.identifier.uri | http://dx.doi.org/10.25673/1347 | - |
dc.description.abstract | Kurzschaftprothesen wurden mit dem Ziel entwickelt einen knochensparenden, minimalinvasiven Hüftgelenkersatz umzusetzen und das von Standardimplantaten bekannte stress-shielding zu vermeiden. Zu untersuchen war, ob die Nanos®-Prothese dieses Ziel realisieren kann. Diesbezüglich wurden 25 Patienten in regelmäßigen Abständen, bis zu einem maximalen follow-up von einem Jahr, einer umfangreichen klinischen, radiologischen und osteodensitometrischen Analyse nach Implantation dieser Prothese unterzogen. Die Osteodensitometrie legte eine signifikante Verminderung der Knochendichte in den GRUEN-Zonen 1, 2 und 7 dar. Bei 12 der 25 Patienten registrierte man radiotransluzente Linien, wobei bei Abwesenheit klinischer Lockerungszeichen von deren Irrelevanz auszugehen war. Die Ergebnisse zeigen, dass die Implantation eines Nanos®-Schaftes die primär angestrebte isolierte metaphysäre Krafteinleitung mit der Schonung der proximalen Calcar-Region nicht umsetzen kann, aber im Vergleich mit anderen Kurzschaftendoprothesen oder konventionellen Implantaten eine verminderte Abnahme der Knochendichte in diesen Regionen erwartet werden kann. | - |
dc.description.abstract | Short-stemmed femoral prosthesis were designed with the aim to realise are duced bone-loss, minimum-invasive total hip arthroplasty and to avoid the stress-shielding known by standard implants. This study analyze, whether the Nanos®stem can realise this aim. 25 patients were examined clinically and radiologically after 3, 6 and 12 months.The DEXA scans showed a significant and relevant decrease in bone-mineral-density in GRUEN zone 1, 2 and 7.15 radiotranslucent lines were noted in 12 cases, but with the absence of clinical signs of loosening, they were regarded as clinically not important.These results point out the Nanos® prosthesis can ´t achieves an exclusive proximal load transfer in the femoral metaphysis with the prevention of stress-shielding. But inliterature comparison to results of other short-stemmed femoral implants or conventional stems, the Nanos® prosthesis can reduce loss of BMD in the proximal femur. | eng |
dc.description.statementofresponsibility | von Franziska Pankow | - |
dc.format.extent | Online-Ressource (87 Bl. = 1,26 mb) | - |
dc.language.iso | ger | - |
dc.publisher | Universitäts- und Landesbibliothek Sachsen-Anhalt | - |
dc.rights.uri | http://rightsstatements.org/vocab/InC/1.0/ | - |
dc.subject | Online-Publikation | - |
dc.subject | Hochschulschrift | - |
dc.subject.ddc | 617 | - |
dc.subject.ddc | 610 | - |
dc.title | Prospektive Studie zur Untersuchung der Osseointegration und Krafteinleitung der Nanos®-Schenkelhalsprothese | - |
dcterms.dateAccepted | 2014-10-09 | - |
dcterms.type | Hochschulschrift | - |
dc.type | PhDThesis | - |
dc.identifier.urn | urn:nbn:de:gbv:3:4-13212 | - |
local.publisher.universityOrInstitution | Martin-Luther-Universität Halle-Wittenberg | - |
local.subject.keywords | Nanos; Kurzschaftprothese; DEXA; Osseointegration | - |
local.subject.keywords | Nanos; THA; DEXA; osseointegration | eng |