Please use this identifier to cite or link to this item: http://dx.doi.org/10.25673/1775
Full metadata record
DC FieldValueLanguage
dc.contributor.refereeWohlrab, David, Prof. Dr.-
dc.contributor.refereeKlinger, Hans-Michael, Prof. Dr.-
dc.contributor.refereeRoth, Andreas, Prof. Dr.-
dc.contributor.authorDietz, Julia-
dc.date.accessioned2018-09-24T11:31:47Z-
dc.date.available2018-09-24T11:31:47Z-
dc.date.issued2016-
dc.identifier.urihttps://opendata.uni-halle.de//handle/1981185920/8546-
dc.identifier.urihttp://dx.doi.org/10.25673/1775-
dc.description.abstractZiel dieser retrospektiven monozentrischen Studie war es klinische und radiologische Langzeitergebnisse der Mayo®-Kurzschaftprothese zu erheben. Wir schlossen 51 Patienten und 61 Hüftprothesen, die von 2000 bis 2003 implantiert wurden, ein. Der Harris Hip Score (HHS) erfasste Patientenzufriedenheit und Funktionalität. Der Forgotten Joint Score (FJS) erfasste die Wahrnehmung des Kunstgelenkes im Alltag. Anhand von Röntgenaufnahmen wurde die Rekonstruktion von Beinlänge, Schaftposition, femoralem Offset und Drehzentrum geprüft. Das Vorhandensein von radioluzenten Linien und periartikulären Ossifikationen wurde analysiert. Nach im Mittel 164 Monaten zeigten sich im HHS 84 Punkte und im FJS 68%. Die Beinlänge wurde nicht wesentlich verändert. Die Schaftposition war 1,6° valgisch. Das femorale Offset wurde um 6 mm vergrößert und das Rotationszentrum um 6 mm medialisiert. Bei 14 Fällen traten radioluzente Linien in den Gruen-Zonen 1, 2, 3 und/oder 7 auf. Periartikuläre Ossifikationen lagen bei 27 Mayo®-Prothesen in den Stadien 1-3 nach Brooker vor. Der Mayo®-Schaft ist ein zuverlässiges Implantat mit vergleichbaren Langzeitergebnissen.-
dc.description.abstractThe goal of this retrospective mono center study was to analyze the clinical and radiological long term results of the Mayo® short stem prosthesis. We included 51 patients with 61 Mayo® hip replacements which were performed from 2000 to 2003. Using the Harris Hip Score (HHS) we measured patient´s satisfaction and hip function. The Forgotten Joint Score (FJS) was used recording the awareness of the hip joint in every day’s life. Based on radiographs the reconstruction of leg length, stem positioning, femoral offset and center of rotation (COR) were proved. The occurrence of radiolucent lines and heterotopic ossifications were noted. Mean follow up was 164 months. For the HHS we measured an average of 84 points and for the FJS 68%. Leg length discrepancy wasn´t measured. There was a mean stem position of 1,6° valgus. The femoral offset increased by an average of 6 mm. The COR was medialized by an average of 6 mm. In 14 hips radiolucent lines appeared in Gruen-Zones 1, 2, 3 and/or 7. Heterotopic ossifications were detected in 27 Mayo® stems at stage 1 to 3 using Brooker classification. The Mayo® prosthesis is a reliable stem with comparable long term results.eng
dc.description.statementofresponsibilityvorgelegt von Julia Dietz-
dc.format.extent1 Online-Ressource (90 Blatt = 1,12 MB)-
dc.language.isoger-
dc.publisherUniversitäts- und Landesbibliothek Sachsen-Anhalt-
dc.rights.urihttp://rightsstatements.org/vocab/InC/1.0/-
dc.subject.ddc610-
dc.titleKlinische und radiologische Langzeitergebnisse der Mayo®-Kurzschaftendoprothese-
dcterms.dateAccepted2016-07-05-
dcterms.typeHochschulschrift-
dc.typePhDThesis-
dc.identifier.urnurn:nbn:de:gbv:3:4-17683-
local.publisher.universityOrInstitutionMartin-Luther-Universität Halle-Wittenberg-
local.subject.keywordsMayo®-Schaft; Kurzschaft; Hüfttotalendoprothese; Langzeitergebnisse-
local.subject.keywordsMayo® stem; short stem; hip replacement; long term resultseng
local.openaccesstrue-
dc.identifier.ppn863184553-
local.accessrights.dnbfree-
Appears in Collections:Medizin und Gesundheit

Files in This Item:
File Description SizeFormat 
Version für ULB final.pdf1.15 MBAdobe PDFThumbnail
View/Open