dc.description.abstract | Die Punktionseigenschaften zwischen den 22 G Standardnadeln (0,7 mm) und den 29 G Nadeln (0,34 mm) wurden verglichen. 17 menschliche chorioamniotische Membranen wurden direkt nach einem Kaiserschnitt punktiert, wobei eine 22 G Nadel sowie eine 29 G Nadel unter In-vitro-Bedingungen verwendet wurden. Das Punktionsgebiet wurde durch Zuhilfenahme eines Mikroskops bestimmt und das Volumen der entweichenden Flüssigkeit über einen Zeitraum von 5 min gemessen. Beachtliche Unterschiede wurden beobachtet: Aus der Membranpunktion mit der 22 G Nadel resultierte eine durchschnittlich beschädigte Oberfläche von 225.147,4 μm2, ein Loch mit einer durchschnittlichen Größe von 50.154 μm2 sowie ein Durchfluss des Fruchtwassers von 17,5 ml/5 min, während die 29 G Nadel lediglich eine durchschnittlich beschädigte Oberfläche von 114.812,4 μm2, ein Loch mit einer durchschnittlichen Größe von 1382,5 μm2 sowie einen Durchfluss des Fruchtwassers von 0,28 ml/5 min verursachte. Das Loch, welches bei der Membranpunktion mit einer 29 G “pencil-point” Nadel für die Amniozentese entsteht, ist 36-mal kleiner und der Fruchtwasserverlust 61-mal geringer als bei der Membranpunktion mit einer 22 G Standardnadel. Mit der 29-G-Nadel wird eine signifikante Verringerung der Komplikationen nach der Amniozentese erwartet. | ger |
dc.description.abstract | Perforation characteristics of standard 22 G (0.7 mm) to 29 G needle (0.34 mm) for amniocentesis have been compared. Seventeen human chorio-amnion membranes were perforated immediately after cesarean section using 22 G needle for spinal anesthesia and 29 G "pencil-point" needles for amniocentesis under in-vitro conditions. Area of perforation was determined using a microscope and volume of fluid leakage was measured over a period of 5 min. Membrane perforation with the 22 G needle resulted in a mean damaged area of 225,147.4 μm(2), a hole with a mean area of 50,154 μm(2) and amniotic fluid volume passage of 17.5 mL/5 min, whereas the 29 G needle generated a mean damaged area of 114,812.4 μm(2), a hole with an average area of 1382.5 μm(2) and volume passage of 0.28 mL/5 min. These differences were significant. The hole formed by membrane perforation with 29 G "pencil-point" needle for amniocentesis is 36 times smaller, and the amniotic fluid loss is 61 times less than that measured with the 22 G standard needle for spinal anesthesia. Significant reduction of complications following amniocentesis is expected with the 29 G needle. | eng |
dc.format.extent | 1 Online-Ressource (61 Seiten) | - |
dc.language.iso | ger | - |
dc.rights.uri | http://rightsstatements.org/vocab/InC/1.0/ | - |
dc.subject.ddc | 610 | - |
dc.title | Evidenzbasierte Einführung der atraumatischen 29-gauge Nadel für Amniozentese | ger |
dcterms.dateAccepted | 2018-09-05 | - |
dcterms.type | Hochschulschrift | - |
dc.type | PhDThesis | - |
dc.identifier.urn | urn:nbn:de:gbv:3:4-1981185920-873438 | - |
local.versionType | publishedVersion | - |
local.publisher.universityOrInstitution | Martin-Luther-Universität Halle-Wittenberg | - |
local.subject.keywords | 29 Gauge; Amniozentesis; Komplikationen; Membranpunktion, Nadel | - |
local.subject.keywords | 29 gauge; amniocentesis; complications; membrane perforation; needle | - |
local.openaccess | true | - |
dc.identifier.ppn | 180108355X | - |
local.publication.country | XA-DE | - |
cbs.sru.importDate | 2022-05-06T07:49:25Z | - |
local.accessrights.dnb | free | - |
Appears in Collections: | Interne-Einreichungen |
Files in This Item:
File | Description | Size | Format | |
---|---|---|---|---|
Doktorarbeit Gatopoulos Bibliothek.pdf | 1.15 MB | Adobe PDF | View/Open |