Bitte benutzen Sie diese Kennung, um auf die Ressource zu verweisen:
http://dx.doi.org/10.25673/2541
Langanzeige der Metadaten
DC Element | Wert | Sprache |
---|---|---|
dc.contributor.author | Karatschai, Ralf Mazen | - |
dc.date.accessioned | 2018-09-24T13:20:17Z | - |
dc.date.available | 2018-09-24T13:20:17Z | - |
dc.date.issued | 2006 | - |
dc.identifier.uri | https://opendata.uni-halle.de//handle/1981185920/9326 | - |
dc.identifier.uri | http://dx.doi.org/10.25673/2541 | - |
dc.description.abstract | Die transkranielle Dopplersonographie (TCD) ist eine wichtige nicht-invasive Untersuchungsmethode zur hämodynamischen Statuserhebung der basalen hirnversorgenden Gefäße. Ein suffizientes temporales Schallfenster wird dazu benötigt, ist aber in 5(-10)% der Fälle nicht bzw. unzureichend vorhanden. Eine Senkung der Trägerfrequenz verringert die Reflektion des Ultraschalls, verbessert jedoch die Durchdringungsfähigkeit durch Knochen. Ziel: Es sollte untersucht werden, ob unter Verwendung einer neuen Sonde mit 1-MHz anstatt 2-MHz Trägerfrequenz die klinische Anwendbarkeit der TCD erweitert wird. Unterschiede der Sonden in der Geschwindigkeitsmessung sollten ausgeschlossen werden. Material und Methoden: 50 Patienten (34 Frauen, 16 Männer; 65 +/- 2 Jahre) mit insgesamt 90 insuffizienten Schallfenstern bei Untersuchung mit 2 MHz wurden mit 1 MHz erneut untersucht. Zusätzlich wurden 50 Kontrollpersonen (16 Frauen, 34 Männer; 49 +/- 2 Jahre) mit beiden Ultraschallsonden untersucht. Beurteilt wurde die Qualität der Darstellung [sehr gut (+++), mäßig (++), schlecht (+)], die gemessenen Geschwindigkeiten beider Sonden wurden anhand dreißig Personen der Kontrollgruppe verglichen. Ergebnisse: Unter Verwendung einer 1-MHz-Sonde konnte in der Untersuchungsgruppe die Arteria cerebri media (MCA) in 76% (68 Fälle; +, n=13; ++, n=29, +++, n=26), die Arteria cerebri anterior (ACA) in 57% (51 Fälle; +, n=23; ++, n=17, +++, n=11) und die Arteria cerebri posterior (PCA) in 51% (46 Fälle; +, n=12; ++, n=21, +++, n=13) neu dargestellt werden. In der Kontrollgruppe war die Untersuchung bei minimalen Qualitätsunterschieden gleich gut möglich. Unterschiede der gemessenen Geschwindigkeiten waren nicht signifikant (MCA p=0.54; ACA p=0.1; PCA p=0.42). Schlussfolgerung: Die Verwendung der 1-MHz-Sonde erweitert die Anwendbarkeit der TCD bei insuffizientem oder nicht vorhandenem Schallfenster. | - |
dc.description.abstract | Transcranial Doppler sonography (TCD) is an important non-invasive method to measure the hemodynamics of intracranial brain supplying arteries. A sufficient temporal bone window is needed, but proves insufficient or absent in 5(-10)%. Reducing transducer frequency results in lesser reflection but better penetration through the bone. Objecitve: To examine the diagnostic yield of trancranial Doppler sonography by using a new probe with 1MHz instead of 2 MHz transducer frequency. To evaluate potential differences in measured flow velocities between both transducers. Material: Fifty outpatients (34 women, 16 men; mean age, 65 +/- 2) representing 90 inadequate temporal bone window for examination with 2-MHz transducers were re-examined with a 1-MHz transducer. Additionally, 50 controls (34 men, 16 women; mean age 49 +/- 2) with adequate temporal bone window were examined with both the 1- and 2-MHz transducers. Signal quality was classified as good (+++), adequate (++), or poor (++). Velocity measures acquired with both transducers in 30 control persons were compared. Results: Use of the 1-MHz transducer resulted in identification of the middle cerebral artery (MCA) in 76% (68 cases; +, n = 13; ++, n = 29; +++, n = 26), the anterior cerebral artery (ACA) in 57% (51 cases; + n = 23; ++, n = 17; +++, n = 11) and the posterior cerebral artery (PCA) in 51% (46 cases; +, n = 12; ++, n = 21; +++, n = 13). Examination was feasible with both transducers in the 50 controls, with minimal differences in signal quality between the two transducers. Differences between velocity values acquired with the 1- and 2-MHz transducers were insignificant (MCA p=0.54; ACA p=0.1; PCA p=0.42). Conclusion: Use of the 1-MHz transducer increases the yield of transcranial Doppler sonography in case of absent or insufficient temporal bone window. | eng |
dc.description.statementofresponsibility | von Ralf Mazen Karatschai | - |
dc.format.extent | Online-Ressource, Text + Image | - |
dc.language.iso | ger | - |
dc.publisher | Universitäts- und Landesbibliothek Sachsen-Anhalt | - |
dc.rights.uri | http://rightsstatements.org/vocab/InC/1.0/ | - |
dc.subject | Elektronische Publikation | - |
dc.subject | Hochschulschrift | - |
dc.subject | Online-Publikation | - |
dc.subject | Zsfassung in engl. Sprache | - |
dc.subject.ddc | 616.075 | - |
dc.title | Anwendbarkeit einer 1-MHz-Sonde in der transkraniellen Dopplersonographie | - |
dcterms.type | Hochschulschrift | - |
dc.type | PhDThesis | - |
dc.identifier.urn | urn:nbn:de:gbv:3-000010241 | - |
local.publisher.universityOrInstitution | Martin-Luther-Universität Halle-Wittenberg | - |
local.subject.keywords | Transkranielle Dopplersonographie, TCD, temporales Schallfenster, Trägerfrequenz, 1 MHz | - |
local.subject.keywords | Transcranial Doppler sonography, TCD, temporal bone window, transducer frequency, 1 MHz | eng |
local.openaccess | true | - |
dc.identifier.ppn | 514144556 | - |
local.accessrights.dnb | free | - |
Enthalten in den Sammlungen: | Hochschulschriften bis zum 31.03.2009 |
Dateien zu dieser Ressource:
Datei | Beschreibung | Größe | Format | |
---|---|---|---|---|
prom.pdf | 315.47 kB | Adobe PDF | ![]() Öffnen/Anzeigen |