Titel: Safety and audiological outcome in a case series of tertiary therapy of sudden hearing loss with a biodegradable drug delivery implant for controlled release of dexamethasone to the inner ear
Autor(en): Plontke, Stefan K.-R.In der Gemeinsamen Normdatei der DNB nachschlagen
Liebau, Arne
Lehner, EricIn der Gemeinsamen Normdatei der DNB nachschlagen
Bethmann, Daniel
Mäder, KarstenIn der Gemeinsamen Normdatei der DNB nachschlagen
Rahne, TorstenIn der Gemeinsamen Normdatei der DNB nachschlagen
Erscheinungsdatum: 2022
Art: Artikel
Sprache: Englisch
Zusammenfassung: Background: Intratympanic injections of glucocorticoids have become increasingly common in the treatment of idiopathic sudden sensorineural hearing loss (ISSHL). However, due to their fast elimination, sustained applications have been suggested for local drug delivery to the inner ear. Materials and methods: The study is based on a retrospective chart review of patients treated for ISSHL at a single tertiary (university) referral center. We included patients who were treated with a solid, biodegradable, poly(D,L-lactic-co-glycolic acid) (PLGA)-based drug delivery system providing sustained delivery of dexamethasone extracochlear into the round window niche (n = 15) or intracochlear into scala tympani (n = 2) for tertiary therapy of ISSHL in patients without serviceable hearing after primary systemic and secondary intratympanic glucocorticoid therapy. We evaluated the feasibility and safety through clinical evaluation, histological examination, and functional tests [pure-tone threshold (PTA), word recognition scores (WRS)]. Results: With adequate surgical preparation of the round window niche, implantation was feasible in all patients. Histologic examination of the material in the round window niche showed signs of resorption without relevant inflammation or foreign body reaction to the implant. In patients where the basal part of scala tympani was assessable during later cochlear implantation, no pathological findings were found. In the patients with extracochlear application, average preoperative PTA was 84.7 dB HL (SD: 20.0) and 76.7 dB HL (SD: 16.7) at follow-up (p = 0.08). The preoperative average maximum WRS was 14.6% (SD: 17.9) and 39.3% (SD: 30.7) at follow-up (p = 0.11). Six patients (40%), however, reached serviceable hearing. The two patients with intracochlear application did not improve. Conclusion: The extracochlear application of the controlled release system in the round window niche and – based on limited observations - intracochlear implantation into scala tympani appears feasible and safe. Due to the uncontrolled study design, conclusions about the efficacy of the treatment are limited. These observations, however, may encourage the initiation of prospective controlled studies using biodegradable controlled release implants as drug delivery systems for the treatment of inner ear diseases.
URI: https://opendata.uni-halle.de//handle/1981185920/112260
http://dx.doi.org/10.25673/110305
Open-Access: Open-Access-Publikation
Nutzungslizenz: (CC BY 4.0) Creative Commons Namensnennung 4.0 International(CC BY 4.0) Creative Commons Namensnennung 4.0 International
Journal Titel: Frontiers in neuroscience
Verlag: Frontiers Research Foundation
Verlagsort: Lausanne
Band: 16
Originalveröffentlichung: 10.3389/fnins.2022.892777
Seitenanfang: 1
Seitenende: 18
Enthalten in den Sammlungen:Open Access Publikationen der MLU

Dateien zu dieser Ressource:
Datei Beschreibung GrößeFormat 
fnins-16-892777.pdf13.87 MBAdobe PDFMiniaturbild
Öffnen/Anzeigen