Titel: | Auscultation system for acquisition of vascular sounds : towards sound-based monitoring of the carotid artery |
Autor(en): | Sühn, Thomas Spiller, Moritz Salvi, Rutuja Hellwig, Stefan Boese, Axel ![]() Illanes, Alfredo Friebe, Michael ![]() |
Erscheinungsdatum: | 2020 |
Art: | Artikel |
Sprache: | Englisch |
URN: | urn:nbn:de:gbv:ma9:1-1981185920-363881 |
Schlagwörter: | Computer-assisted auscultation Vascular disease Long- term monitoring Stenosis |
Zusammenfassung: | Introduction: Atherosclerotic diseases of the carotid are a primary cause of cerebrovascular events such as stroke. For the diagnosis and monitoring angiography, ultrasound- or magnetic resonance-based imaging is used which requires costly hardware. In contrast, the ausculta-tion of carotid sounds and screening for bruits – audible patterns related to turbulent blood flow – is a simple examination with comparably little technical demands. It can indicate atherosclerotic diseases and justify further diagnostics but is currently subjective and exam-iner dependent.Methods: We propose an easy-to-use computer-assisted auscultation system for a stable and reproducible acquisition of vascular sounds of the carotid. A dedicated skin-transducer- interface was incorporated into a handheld device. The interface comprises two bell-shape d structures, one with additional acoustic membrane, to ensure defined skin contact and a stable propagation path of the sound. The device is connected wirelessly to a desktop application allowing real-time visualization, assessment of signal quality and input of supplementary information along with storage of recordings in a database. An experimental study with 5 healthy subjects was conducted to evaluate usability and stability of the device. Five recordings per carotid served as data basis for a wavelet-based analysis of the stability of spectral characteristics of the recordings.Results: The energy distribution of the wavelet-based stationary spectra proved stable for measurements of a particular carotid with the majority of the energy located between 3 and 40 Hz. Different spectral properties of the carotids of one individual indicate the presence of sound characteristics linked to the particular vessel. User-dependent parameters such as variations of the applied contact pressure appeared to have minor influence on the general stability.Conclusion: The system provides a platform for reproducible carotid auscultation and the creation of a database of pathological vascular sounds, which is a prerequisite to investigate sound-based vascular monitoring. |
URI: | https://opendata.uni-halle.de//handle/1981185920/36388 http://dx.doi.org/10.25673/36155 |
Open-Access: | ![]() |
Nutzungslizenz: | ![]() |
Sponsor/Geldgeber: | DFG-Publikationsfonds 2020 |
Journal Titel: | Medical devices |
Verlag: | Dove Medical Press |
Verlagsort: | Macclesfield [u.a.] |
Band: | 13 |
Originalveröffentlichung: | 10.2147/MDER.S268057 |
Seitenanfang: | 349 |
Seitenende: | 364 |
Enthalten in den Sammlungen: | Medizinische Fakultät (OA) |