Titel: | Influence of electromagnetic radiation emitted by daily-use electronic devices on the Eyemate® system in-vitro : a feasibility study |
Autor(en): | Invernizzi, Azzurra Haykal, Shereif Lo Faro, Valeria Pennisi, Vincenzo Choritz, Lars |
Erscheinungsdatum: | 2020 |
Art: | Artikel |
Sprache: | Englisch |
URN: | urn:nbn:de:gbv:ma9:1-1981185920-365285 |
Schlagwörter: | Intraocular pressure Electromagnetic radiation Glaucoma Eyemate® system |
Zusammenfassung: | Background: Eyemate® is a system for the continual monitoring of intraocular pressure (IOP), composed of an intraocular sensor, and a hand-held reader device. As the eyemate®-IO sensor communicates with the hand-held reader telemetrically, some patients might fear that the electronic devices that they use on a daily basis might somehow interfere with this communication, leading to unreliable measurements of IOP. In this study, we investigated the effect of electromagnetic radiation produced by a number of everyday electronic devices on the measurements made by an eyemate®-IO sensor in-vitro, in an artificial and controlled environment. Methods: The eyemate®-IO sensor was suspended in a sterile 0.9% sodium chloride solution and placed in a water bath at 37 °C. The antenna, connected to a laptop for recording the data, was positioned at a fixed distance of 1 cm from the sensor. Approximately 2 hrs of “quasi-continuous” measurements were recorded for the baseline and for a cordless phone, a smart-phone and a laptop. Repeated measures ANOVA was used to compare any possible differences between the baseline and the tested devices. Results: For baseline measurements, the sensor maintained a steady-state, resulting in a flat profile at a mean pressure reading of 0.795 ± 0.45 hPa, with no apparent drift. No statistically significant difference (p = 0.332) was found between the fluctuations in the baseline and the tested devices (phone: 0.76 ± 0.41 hPa; cordless: 0.787 ± 0.26 hPa; laptop: 0.775 ± 0.39 hPa). Conclusion: In our in-vitro environment, we found no evidence of signal drifts or fluctuations associated with the tested devices, thus showing a lack of electromagnetic interference with data transmission in the tested frequency ranges. |
URI: | https://opendata.uni-halle.de//handle/1981185920/36528 http://dx.doi.org/10.25673/36295 |
Open-Access: | Open-Access-Publikation |
Nutzungslizenz: | (CC BY 4.0) Creative Commons Namensnennung 4.0 International |
Sponsor/Geldgeber: | DFG-Publikationsfonds 2020 |
Journal Titel: | BMC ophthalmology |
Verlag: | BioMed Central |
Verlagsort: | London |
Band: | 20 |
Heft: | 2020 |
Originalveröffentlichung: | 10.1186/s12886-020-01623-6 |
Seitenanfang: | 1 |
Seitenende: | 6 |
Enthalten in den Sammlungen: | Medizinische Fakultät (OA) |
Dateien zu dieser Ressource:
Datei | Beschreibung | Größe | Format | |
---|---|---|---|---|
Invernizzi et al._Influence_2020.pdf | Zweitveröffentlichung | 1 MB | Adobe PDF | Öffnen/Anzeigen |