Please use this identifier to cite or link to this item: http://dx.doi.org/10.25673/40028
Title: Der Einfluss von verschiedenen Spüllösungen auf den Haftverbund von Dentinadhäsiven auf humanen Dentinproben : eine In-vitro-Studie
Author(s): Hünecke, Franziska Kristin ClaudiaLook up in the Integrated Authority File of the German National Library
Referee(s): Gernhardt, ChristianLook up in the Integrated Authority File of the German National Library
Schaller, Hans-Günter
Wrbas, Karl-ThomasLook up in the Integrated Authority File of the German National Library
Granting Institution: Martin-Luther-Universität Halle-Wittenberg
Issue Date: 2021
Extent: 1 Online-Ressource (85 Seiten)
Type: HochschulschriftLook up in the Integrated Authority File of the German National Library
Type: PhDThesis
Exam Date: 2021-10-04
Language: German
URN: urn:nbn:de:gbv:3:4-1981185920-419821
Abstract: Die Studie untersucht an humanen Dentinproben den Einfluss der Spüllösungen NaOCl, CHX, EDTA sowie die Anfrischung des Dentins mit Glycin-Pulver nach dem Spülprotokoll, auf den Haftverbund von Adhäsiven. Methodik: 270 Dentinproben aus Weisheitszähnen wurden in 18 Gruppen unterteilt. Nach Vorbehandlung mit den Spüllösungen bzw. der Anfrischung mit Glycin erfolgte die Applikation der Adhäsive (Futurabond U, Solobond M), des Komposits (GrandioSO x-tra U) und die Messung der Mikrozugfestigkeiten. Ergebnisse: Bei Futurabond U ist in Kombination mit NaOCl eine signifikante Reduktion der Mikrozugfestigkeiten deutlich geworden. CHX führt nur bei Solobond M zu einer signifikanten Steigerung der Haftung. Die Wechselspülung mit EDTA und NaOCl reduziert bei Futurabond U die Haftung signifikant. Schlussfolgerung: Die Spüllösungen haben einen Einfluss auf den Haftverbund. Eine Anfrischung mit Glycin-Pulver nach einem Spülprotokoll führt nicht zu einer signifikanten Verbesserung der Haftung.
The study investigated the influence of the rinsing solutions NaOCl, CHX, EDTA as well as refreshing the dentin with glycine powder after the rinsing protocol on the bond strength of adhesives in human dentin samples. Methods: 270 dentin samples from third molars were divided into 18 groups. After pretreatment with the rinsing solutions or freshening with glycine, the adhesives (Futurabond U, Solobond M), the composite (GrandioSO x-tra U) were applied and the microtensile bond strengths were measured. Results: With Futurabond U, a significant reduction in microtensile bond strengths became evident in combination with NaOCl. CHX leads to a significant increase in adhesion only with Solobond M. Alternating rinsing with EDTA and NaOCl significantly reduces the adhesion of Futurabond U. Conclusion: The rinsing solutions have an influence on the adhesive bond. Freshening with glycine powder after a rinsing protocol does not significantly improve adhesion.
URI: https://opendata.uni-halle.de//handle/1981185920/41982
http://dx.doi.org/10.25673/40028
Open Access: Open access publication
License: In CopyrightIn Copyright
Appears in Collections:Interne-Einreichungen

Files in This Item:
File Description SizeFormat 
Dissertation Korrektur Franziska Hünecke.pdf818.14 kBAdobe PDFThumbnail
View/Open