Title: Reproduction of a conventional anthropomorphic female chest phantom by 3D-printing : comparison of image contrasts and absorbed doses in CT
Author(s): Kunert, Patrizia
Schlattl, HelmutLook up in the Integrated Authority File of the German National Library
Trinkl, Sebastian
Giussani, Augusto
Klein, Lea
Janich, MartinLook up in the Integrated Authority File of the German National Library
Reichert, DetlefLook up in the Integrated Authority File of the German National Library
Brix, GunnarLook up in the Integrated Authority File of the German National Library
Issue Date: 2023
Type: Article
Language: English
Abstract: Background: The production of individualized anthropomorphic phantoms via three-dimensional (3D) printing methods offers promising possibilities to assess and optimize radiation exposures for specifically relevant patient groups (i.e., overweighed or pregnant persons) that are not adequately represented by standardized anthropomorphic phantoms. However, the equivalence of printed phantoms must be demonstrated exemplarily with respect to the resulting image contrasts and dose distributions. Purpose: To reproduce a conventionally produced anthropomorphic phantom of a female chest and breasts and to evaluate their equivalence with respect to image contrasts and absorbed doses at the example of a computed tomography (CT) examination of the chest. Methods: In a first step, the effect of different print settings on the CT values of printed samples was systematically investigated. Subsequently, a transversal slice and breast add-ons of a conventionally produced female body phantom were reproduced using a multi-material extrusion-based printer, considering six different types of tissues (muscle, lung, adipose, and glandular breast tissue, as well as bone and cartilage). CT images of the printed and conventionally produced phantom parts were evaluated with respect to their geometric correspondence, image contrasts, and absorbed doses measured using thermoluminescent dosimeters. Results: CT values of printed objects are highly sensitive to the selected print settings. The soft tissues of the conventionally produced phantom could be reproduced with a good agreement. Minor differences in CT values were observed for bone and lung tissue, whereas absorbed doses to the relevant tissues were identical within the measurement uncertainties. Conclusion: 3D-printed phantoms are with exception of minor contrast differences equivalent to their conventionally manufactured counterparts. When comparing the two production techniques, it is important to note that conventionally manufactured phantoms should not be considered as absolute benchmarks, as they also only approximate the human body in terms of its absorption, and attenuation of x-rays as well as its geometry.
URI: https://opendata.uni-halle.de//handle/1981185920/112222
http://dx.doi.org/10.25673/110267
Open Access: Open access publication
License: (CC BY-NC-ND 4.0) Creative Commons Attribution NonCommercial NoDerivatives 4.0(CC BY-NC-ND 4.0) Creative Commons Attribution NonCommercial NoDerivatives 4.0
Journal Title: Medical physics
Publisher: Wiley
Publisher Place: Hoboken, NJ
Volume: 50
Issue: 8
Original Publication: 10.1002/mp.16587
Page Start: 4734
Page End: 4743
Appears in Collections:Open Access Publikationen der MLU

Files in This Item:
File Description SizeFormat 
Medical Physics - 2023 - Kunert.pdf1.48 MBAdobe PDFThumbnail
View/Open